dscADSample()
Performs a single A/D conversion on the currently selected channel. The function first waits for the board to be ready for a conversion. It then starts the conversion and waits for it to finish before reading data from the board. A built-in timer is used to check for board failure. If the timer times out before the conversion completes, the board returns the error code.
Name | Description |
board | The handle of the board to operate on |
sample | The sample resulting from the A/D conversion; the range of return values depends on the type of A/D board. |
Return Value |
Error code or 0. |