8.2 Input Ranges and Resolution

The table below lists the full-scale input range for each valid analog input configuration. The parameters Polarity, Range, and Gain are combined to create the value “Code”, which is the value that you must write to the analog configuration register at Base + 11 to get the input range shown. A total of 9 different input ranges are possible. Note that the range programming codes 4, 5, 6, and 7 are invalid and that range codes 9 – 11 are equivalent to range codes 0 – 2.

Diamond-MM-32DX-AT Analog Input Ranges

Polarity

Range

Gain

Code

Full Scale Range

Resolution (1 LSB)

Bipolar

5V

1

0

+/- 5V

153 μV

Bipolar

5V

2

1

+/-2.5V

76 μV

Bipolar

5V

4

2

+/-1.25V

38 μv

Bipolar

5V

8

3

+/- 0.625V

19μV

Unipolar

5V

1

4

Invalid setting

Unipolar

5V

2

5

Invalid setting

Unipolar

5V

4

6

Invalid setting

Unipolar

5V

8

7

Invalid setting

Bipolar

10V

1

8

+/-10V

305μV

Bipolar

10V

2

9

+/-5V

153μV

Bipolar

10V

4

10

+/-2.5V

76μV

Bipolar

10V

8

11

+/-1.25V

38μV

Unipolar

10V

1

12

0-10V

153μV

Unipolar

10V

2

13

0-5V

76μV

Unipolar

10V

4

14

0-2.5V

38μV

Unipolar

10V

8

15

0-1.25V

19μV