18.3 Output Range Selection

The D/A output range is determined by the values of the register bits DAPOL, DAG!, and DAG0 in the register at page 2 base+14. When a value is written to this register, the D/A range for the selected channel will be set to the selected value. Each D/A channel can have its own range. To set all channels to the same range, set bit DAUR=0 when selecting the output range. To set a channel to its own range, set DAUR=1 and then select the channel using bits DACH1-0

DAPOL

DAG1

DAG0

DAC output range or function

0

0

0

0 to 5V (unipolar 5V span)

1

0

0

±2.5V (bipolar 5V span)

0

0

1

0 to 10V (unipolar 10V span)

1

0

1

±5V (bipolar 10V span)

0

1

0

Not Used – Setting Ignored

1

1

0

±10V (bipolar 20V span)

X

1

1

D/A converter shut down